Product Overview
Highlights:
- Performs periodic self-tests to ensure integrity of GFCI protection if no ground-fault protection is detected, the device will trip, will not reset and the status indicator light will glow amber
- Tapered back wire openings handle multiple wire sizes and types for applications up to NO 10 AWG solid or stranded wire
- When downstream receptacles are wired from load side, a 20 amp feed-through rating offers full protection
- Test and reset buttons are color matched to provide superior aesthetics
- Exclusive built-in wire stripper provides fast stripping of wire without tools
- Tri-combo head terminal and mounting screws
- cULus Listed to UL498 and UL943
- File No E60120, Meets All UL943 (GFCI)
- UL498 (Receptacles) UL20 (switch) and applicable CSA Requirements
- NOM Certified
- Mid-Size WAllplate
Specifications
- Line-load miswiring protection
- GFCIs will not provide power downstream when wired incorrectly
- Color
- Light Almond
- Type
- Self-Test
- Number of Poles
- 2
- Voltage Rating
- 125 Volt
- Number Of Wires
- 3
- Wattage
- 1800 Watt
- Amperage Rating
- 15 A
- Width
- 3.305"
- Wire Size
- 10 AWG
- Depth
- 2.266"
- Frequency Rating
- 60 Hz
- Material
- Polypropylene top, PVC bottom housing
- Short Circuit Rating
- 10
- Nema Rating
- NEMA 5-15R
- Grounding Style
- Automatic
- Number of Outlets
- 1
- Temperature Rating
- -35 TO 66 degree C
- Connection
- Back and Side Wired
- Dielectric Strength
- 2000 V
- Type of Indicators
- Visual
- Overall Length
- 6.197"
- Enclosure Type
- Metal
- Overall Width
- 3.305"
- Overall Depth
- 2.266"
- Terminal Type
- Screw
- Brand
- Cooper Wiring
- Mfr number
- TRSGFS15LA-M-L
- Item number
- 12348465
- UPC
- 032664753053
Shipping & Returns
Shipping calculated at checkout.
Returns accepted within 30 days by mail. Return shipping is paid by the customer. See our refund policy.